virtual-klipper-printer/example-configs/addons/dual_extruder.cfg

55 lines
1.2 KiB
INI

[include basic_extruder.cfg]
[extruder]
step_pin: PB1
dir_pin: !PB0
enable_pin: !PD6
heater_pin: PD5
sensor_pin: PA7
sensor_type: EPCOS 100K B57560G104F
control: watermark
microsteps: 16
rotation_distance: 33.683
nozzle_diameter: 0.400
filament_diameter: 1.750
min_temp: 0
max_temp: 250
min_extrude_temp: 50
max_extrude_only_distance: 50.0
pressure_advance: 0.1
pressure_advance_smooth_time: 0.01
[extruder1]
step_pin: PD3
dir_pin: PD2
enable_pin: !PD6
heater_pin: PB7
sensor_pin: PA1
sensor_type: EPCOS 100K B57560G104F
control: watermark
microsteps: 16
rotation_distance: 33.500
nozzle_diameter: 0.500
filament_diameter: 1.75
min_temp: 0
max_temp: 250
min_extrude_temp: 210
max_extrude_only_distance: 100.0
pressure_advance: 0.2
pressure_advance_smooth_time: 0.02
[gcode_macro T0]
variable_active: 1
gcode:
{ action_respond_info("Switching to T0") }
SET_GCODE_VARIABLE MACRO=T0 VARIABLE=active VALUE=1
SET_GCODE_VARIABLE MACRO=T1 VARIABLE=active VALUE=0
ACTIVATE_EXTRUDER EXTRUDER=extruder
[gcode_macro T1]
variable_active: 0
gcode:
{ action_respond_info("Switching to T1") }
SET_GCODE_VARIABLE MACRO=T0 VARIABLE=active VALUE=0
SET_GCODE_VARIABLE MACRO=T1 VARIABLE=active VALUE=1
ACTIVATE_EXTRUDER EXTRUDER=extruder1