[z_calibration] ## update these variable according to the documentation here https://github.com/protoloft/klipper_z_calibration ## you then should call CALIBRATE_Z as one of the last lines on your PRINT_START to set the Z offset dinamically #probe_nozzle_x: YOUR Z Endstop X #probe_nozzle_y: YOUR Z Endstop X # The X and Y coordinates (in mm) for clicking the nozzle on the # Z endstop. #(probe_switch_x should be minus 5mm from the probe_nozzle_x) #probe_switch_x: #(probe_switch_y should be minus 10.5mm from the probe_nozzle_y) #probe_switch_y: # The X and Y coordinates (in mm) for clicking the probe's switch # on the Z endstop. #probe_bed_x: default from relative_reference_index of bed_mesh #probe_bed_y: default from relative_reference_index of bed_mesh # The X and Y coordinates (in mm) for probing on the print surface # (e.g. the center point) These coordinates will be adapted by the # probe's X and Y offsets. The default is the relative_reference_index # of the configured bed_mesh. It will raise an error if there is no # probe_bed site and no bed_mesh with a relative_reference_index # configured. switch_offset: 0.42 # The trigger point offset of the used klicky switch. # This needs to be fined out manually. More on this later # in this section.. max_deviation: 1.5 # The maximum allowed deviation of the calculated offset. # If the offset exceeds this value, it will stop! # The default is 1.0 mm. #samples: default from [probe] section # The number of times to probe each point. The probed z-values # will be averaged. The default is from the probe's configuration. #samples_tolerance: default from [probe] section # The maximum Z distance (in mm) that a sample may differ from other # samples. The default is from the probe's configuration. #samples_tolerance_retries: default from [probe] section # The number of times to retry if a sample is found that exceeds # samples_tolerance. The default is from the probe's configuration. #samples_result: default from [probe] section # The calculation method when sampling more than once - either # "median" or "average". The default is from the probe's configuration. clearance: 10 # The distance in mm to move up before moving to the next # position. The default is two times the z_offset from the probe's # configuration. position_min: 0 # Minimum valid distance (in mm) used for probing move. The # default is from the Z rail configuration. speed: 100 # The moving speed in X and Y. The default is 50 mm/s. #lift_speed: 100 # Speed (in mm/s) of the Z axis when lifting the probe between # samples and clearance moves. The default is from the probe's # configuration. #probing_speed: default homing_speed from [stepper_z] section. # The fast probing speed (in mm/s) used, when probing_first_fast # is activated. The default is from the Z rail configuration. #probing_second_speed: default second_homing_speed from [stepper_z] section. # The slower speed (in mm/s) for probing the recorded samples. # The default is second_homing_speed of the Z rail configuration. #probing_retract_dist: default homing_retract_dist from [stepper_z] section. # Distance to backoff (in mm) before probing the next sample. # The default is homing_retract_dist from the Z rail configuration. probing_first_fast: true # If true, the first probing is done faster by the probing speed. # This is to get faster down and the result is not recorded as a # probing sample. The default is false. start_gcode: Dock_Probe_Unlock # A list of G-Code commands to execute prior to each calibration command. # See docs/Command_Templates.md for G-Code format. This can be used to # attach the probe. before_switch_gcode: Attach_Probe # A list of G-Code commands to execute prior to each probing on the # mag-probe. See docs/Command_Templates.md for G-Code format. This can be # used to attach the probe after probing on the nozzle and before probing # on the mag-probe. end_gcode: Dock_Probe # A list of G-Code commands to execute after each calibration command. # See docs/Command_Templates.md for G-Code format. This can be used to # detach the probe afterwards. [gcode_macro CALIBRATE_Z] rename_existing: BASE_CALIBRATE_Z gcode: M117 Z-Calibration.. BASE_CALIBRATE_Z M117