Astrodyne inlet rev b (Add warning re: tabs on medical version of inlet) (#372)
* Add warning to readme re: 082SM tabs * Add headings to images
This commit is contained in:
parent
7c5e04fe84
commit
f24b480a92
|
|
@ -5,17 +5,47 @@ Tech
|
|||
IEC-GS-1-100](https://www.digikey.com/en/products/detail/adam-tech/IEC-GS-1-100/9831135)
|
||||
(which has been on back-order at Digikey for quite a while at the time of
|
||||
this writing) with an
|
||||
[Astrodyne
|
||||
082S/082SM](https://www.mouser.com/ProductDetail/astrodyne-tdi/082sm0150000/?qs=eP2BKZSCXI4KQZVxn1eqpw%3D%3D).
|
||||
[Astrodyne/TDI
|
||||
082S](https://www.mouser.com/ProductDetail/Astrodyne-TDI/082S0150000?qs=eP2BKZSCXI7jG836kH3rhw%3D%3D).
|
||||
|
||||
-------
|
||||
|
||||
**WARNING**: I just discovered that the 082SM ("M" for "medical") has small tabs on both sides of
|
||||
the inlet (**not** shown in the datasheet). These tabs physically prevent normal C13 power
|
||||
cords (what the Brits would call "bog standard kettle cords") from fitting into the
|
||||
receptacle. I _think_ but am not yet sure that the 082S (general purpose model)
|
||||
does not have the tabs (I think they are to prevent non-certified
|
||||
cords from being used accidentally). I've ordered an 082S to verify and will
|
||||
update this README once I've confirmed.
|
||||
|
||||
Also, as should be obvious: You will need to acquire and insert 250VAC buss
|
||||
fuses (by pulling out the little drawer — there is a slot for the active
|
||||
fuse, plus room for a spare in the front).
|
||||
|
||||
## View of Tab in 082SM version
|
||||
|
||||

|
||||
|
||||
-------
|
||||
|
||||
## Assembled view
|
||||
|
||||

|
||||
|
||||
## Printed part render
|
||||
|
||||

|
||||
|
||||
## Unassembled view
|
||||
|
||||

|
||||
|
||||
## Front view
|
||||
|
||||

|
||||
|
||||
## Rear view
|
||||
|
||||

|
||||
|
||||
## Printing notes
|
||||
|
|
|
|||
Binary file not shown.
|
After Width: | Height: | Size: 593 KiB |